dell服务器安装PERCCLI

2023-12-08 07:28
文章标签 安装 服务器 dell perccli

本文主要是介绍dell服务器安装PERCCLI,希望对大家解决编程问题提供一定的参考价值,需要的开发者们随着小编来一起学习吧!

因在linux 系统中无法查看系统磁盘的raid级别,也无法得知raid状态,需要安装额外的包来监控,因是dell服务器,就在dell网站中下载并安装

1、下载链接:驱动程序和下载 | Dell 中国icon-default.png?t=N7T8https://www.dell.com/support/home/zh-cn?app=drivers选择产品型号并选择驱动类型

下载的包如下图,下载后上传到/opt目录下

在主机安装并使用

root@hydb opt]# rpm -ivh perccli-1.17.10-1.noarch.rpm
Verifying...                          ################################# [100%]
Preparing...                          ################################# [100%]
Updating / installing...
   1:perccli-1.17.10-1                ################################# [100%]
[root@hydb opt]#

[root@hydb perccli]# ln -s /opt/MegaRAID/perccli/perccli64 /bin/perccli
[root@hydb ~]#

[root@hydb ~]#  perccli /c0/eall/sall show
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive Information :
=================

-------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
-------------------------------------------------------------------------
64:0      2 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:1      0 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:2      1 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:3      4 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:4      3 GHS    -   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
[root@hydb ~]# perccli /c0/vall show
Controller = 0
Status = Success
Description = None


Virtual Drives :
==============

-----------------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name         
-----------------------------------------------------------------------
1/238 RAID1 Optl  RW     No      RWBD  -   OFF   1.818 TB loccalbackup
0/239 RAID1 Optl  RW     Yes     RWBD  -   OFF 446.625 GB              
-----------------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|B=Blocked|Consist=Consistent|
R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
[root@hydb ~]# perccli show ctrlcount
Status Code = 0
Status = Success
Description = None

Controller Count = 1

查看控制器的信息

**perccli show ctrlcount 查看有几个控制器即几个raid卡 **

perccli show 显示raid卡信息
[root@hydb ~]# perccli show
Status Code = 0
Status = Success
Description = None

Number of Controllers = 1
Host Name = dbdg
Operating System  = Linux5.15.0-101.103.2.1.el8uek.x86_64

System Overview :
===============

---------------------------------------------------------------------------
Ctl Model           Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
---------------------------------------------------------------------------
  0 PERCH750Adapter     8   5   2     0   2     0 Opt On  -  N      0 Opt  
---------------------------------------------------------------------------

Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
PDs=Physical drives|DNOpt=DG NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Hot Spare
Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit
Hlth=Health|Safe=Safe-mode boot
[root@hydb ~]# perccli /c0 show
Generating detailed summary of the adapter, it may take a while to complete.

Controller = 0
Status = Success
Description = None

Vendor Id = 0x1000
Device Id = 0x10E2
SubVendor Id = 0x1028
SubDevice Id = 0x2176
Host Interface = PCI-E
Device Interface = SATA-3G
Bus Number = 134
Device Number = 0
Function Number = 0
Drive Groups = 2

TOPOLOGY :
========

--------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT       Size PDC  PI SED DS3  FSpace
--------------------------------------------------------------------------
 0 -   -   -        -   RAID1 Optl  N  446.625 GB dflt N  N   dflt N      
 0 0   -   -        -   RAID1 Optl  N  446.625 GB dflt N  N   dflt N      
 0 0   0   64:0     2   DRIVE Onln  N  446.625 GB dflt N  N   dflt -      
 0 0   1   64:1     0   DRIVE Onln  N  446.625 GB dflt N  N   dflt -      
 1 -   -   -        -   RAID1 Optl  Y    1.818 TB dflt N  N   dflt N      
 1 0   -   -        -   RAID1 Optl  Y    1.818 TB dflt N  N   dflt N      
 1 0   0   64:2     1   DRIVE Onln  N    1.818 TB dflt N  N   dflt -      
 1 0   1   64:3     4   DRIVE Onln  N    1.818 TB dflt N  N   dflt -      
--------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present

Virtual Drives = 2

VD LIST :
=======

-----------------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name         
-----------------------------------------------------------------------
0/239 RAID1 Optl  RW     Yes     RWBD  -   OFF 446.625 GB              
1/238 RAID1 Optl  RW     No      RWBD  -   OFF   1.818 TB loccalbackup
-----------------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|B=Blocked|Consist=Consistent|
R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

Physical Drives = 5

PD LIST :
=======

-------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
-------------------------------------------------------------------------
64:0      2 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:1      0 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:2      1 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:3      4 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:4      3 GHS    -   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


BBU_Info :
========

-------------------------------------------------------------------
Model State   RetentionTime Temp Mode MfgDate Next Learn           
-------------------------------------------------------------------
BBU   Optimal 0 hour(s)     31C  -    0/00/00 2024/02/20  03:22:19
-------------------------------------------------------------------
[root@hydb ~]#
看磁盘的Device id、Slot No. 以及DriveGroup
[root@hydb ~]#  perccli /c0/eall/sall show
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.

Drive Information :
=================

-------------------------------------------------------------------------
EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
-------------------------------------------------------------------------
64:0      2 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:1      0 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
64:2      1 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:3      4 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
64:4      3 GHS    -   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


[root@hydb ~]#
[root@hydb ~]# lsscsi
[0:3:110:0]  disk    DELL     PERC H750 Adp    5.16  /dev/sda
[0:3:111:0]  disk    DELL     PERC H750 Adp    5.16  /dev/sdb
[root@hydb ~]#

这篇关于dell服务器安装PERCCLI的文章就介绍到这儿,希望我们推荐的文章对编程师们有所帮助!



http://www.chinasem.cn/article/469022

相关文章

一文详解如何查看本地MySQL的安装路径

《一文详解如何查看本地MySQL的安装路径》本地安装MySQL对于初学者或者开发人员来说是一项基础技能,但在安装过程中可能会遇到各种问题,:本文主要介绍如何查看本地MySQL安装路径的相关资料,需... 目录1. 如何查看本地mysql的安装路径1.1. 方法1:通过查询本地服务1.2. 方法2:通过MyS

电脑软件不能安装到C盘? 真相颠覆你的认知!

《电脑软件不能安装到C盘?真相颠覆你的认知!》很多人习惯把软件装到D盘、E盘,刻意绕开C盘,这种习惯从哪来?让我们用数据和案例,拆解背后的3大原因... 我身边不少朋友,在使用电脑安装软件的时候,总是习惯性的把软件安装到D盘或者E盘等位置,刻意避开C盘。如果你也有这样的习惯,或者不明白为什么要这么做,那么我

ubuntu20.0.4系统中安装Anaconda的超详细图文教程

《ubuntu20.0.4系统中安装Anaconda的超详细图文教程》:本文主要介绍了在Ubuntu系统中如何下载和安装Anaconda,提供了两种方法,详细内容请阅读本文,希望能对你有所帮助... 本文介绍了在Ubuntu系统中如何下载和安装Anaconda。提供了两种方法,包括通过网页手动下载和使用wg

ubuntu如何部署Dify以及安装Docker? Dify安装部署指南

《ubuntu如何部署Dify以及安装Docker?Dify安装部署指南》Dify是一个开源的大模型应用开发平台,允许用户快速构建和部署基于大语言模型的应用,ubuntu如何部署Dify呢?详细请... Dify是个不错的开源LLM应用开发平台,提供从 Agent 构建到 AI workflow 编排、RA

如何在Ubuntu上安装NVIDIA显卡驱动? Ubuntu安装英伟达显卡驱动教程

《如何在Ubuntu上安装NVIDIA显卡驱动?Ubuntu安装英伟达显卡驱动教程》Windows系统不同,Linux系统通常不会自动安装专有显卡驱动,今天我们就来看看Ubuntu系统安装英伟达显卡... 对于使用NVIDIA显卡的Ubuntu用户来说,正确安装显卡驱动是获得最佳图形性能的关键。与Windo

ubuntu16.04如何部署dify? 在Linux上安装部署Dify的技巧

《ubuntu16.04如何部署dify?在Linux上安装部署Dify的技巧》随着云计算和容器技术的快速发展,Docker已经成为现代软件开发和部署的重要工具之一,Dify作为一款优秀的云原生应用... Dify 是一个基于 docker 的工作流管理工具,旨在简化机器学习和数据科学领域的多步骤工作流。它

Docker安装MySQL镜像的详细步骤(适合新手小白)

《Docker安装MySQL镜像的详细步骤(适合新手小白)》本文详细介绍了如何在Ubuntu环境下使用Docker安装MySQL5.7版本,包括从官网拉取镜像、配置MySQL容器、设置权限及内网部署,... 目录前言安装1.访问docker镜像仓库官网2.找到对应的版本,复制右侧的命令即可3.查看镜像4.启

debian12安装docker的实现步骤

《debian12安装docker的实现步骤》本文主要介绍了debian12安装docker的实现步骤,文中通过示例代码介绍的非常详细,对大家的学习或者工作具有一定的参考学习价值,需要的朋友们下面随着... 目录步骤 1:更新你的系统步骤 2:安装依赖项步骤 3:添加 docker 的官方 GPG 密钥步骤

Win安装MySQL8全过程

《Win安装MySQL8全过程》:本文主要介绍Win安装MySQL8全过程,具有很好的参考价值,希望对大家有所帮助,如有错误或未考虑完全的地方,望不吝赐教... 目录Win安装mysql81、下载MySQL2、解压文件3、新建文件夹data,用于保存数据库数据文件4、在mysql根目录下新建文件my.ini

Go语言开发实现查询IP信息的MCP服务器

《Go语言开发实现查询IP信息的MCP服务器》随着MCP的快速普及和广泛应用,MCP服务器也层出不穷,本文将详细介绍如何在Go语言中使用go-mcp库来开发一个查询IP信息的MCP... 目录前言mcp-ip-geo 服务器目录结构说明查询 IP 信息功能实现工具实现工具管理查询单个 IP 信息工具的实现服