HP C7000刀片服务器北电GbE2c背板网络交换机更改用户名密码

本文主要是介绍HP C7000刀片服务器北电GbE2c背板网络交换机更改用户名密码,希望对大家解决编程问题提供一定的参考价值,需要的开发者们随着小编来一起学习吧!

HP C7000刀片服务器使用的GbE2c刀片背板网络交换机和传统的华为、思科等厂商设备的配置方式很不一样,配置起来比较复杂,本文是对其进行用户密码修改的样例。

1、字符界面修改

北电的命令行为层级式菜单操作,cd命令可以返回到根级,cd ..可以返回到上一级

通过telnet到设备上进行操作:

------------------------------------------------------------
[Main Menu]Jan  3 18:00:12 10.193.199.4 NOTICE  mgmt: admin(admin) login from host 10.227.17.234info     - Information Menustats    - Statistics Menucfg      - Configuration Menuoper     - Operations Command Menuboot     - Boot Options Menumaint    - Maintenance Menudiff     - Show pending config changes  [global command]apply    - Apply pending config changes [global command]save     - Save updated config to FLASH [global command]revert   - Revert pending or applied changes [global command]exit     - Exit  [global command, always available]>> Main# cfg
------------------------------------------------------------
[Configuration Menu]sys      - System-wide Parameter Menuport     - Port Menuqos      - QOS Menuacl      - Access Control List Menupmirr    - Port Mirroring Menul2       - Layer 2 Menul3       - Layer 3 Menurmon     - RMON Menuufd      - Uplink Failure Detection Menusetup    - Step by step configuration set updump     - Dump current configuration to script fileptcfg    - Backup current configuration to FTP/TFTP servergtcfg    - Restore current configuration from FTP/TFTP servercur      - Display current configuration>> Configuration# sys
------------------------------------------------------------
[System Menu]syslog   - Syslog Menusshd     - SSH Server Menuradius   - RADIUS Authentication Menutacacs+  - TACACS+ Authentication Menuntp      - NTP Server Menussnmp    - System SNMP Menuaccess   - System Access Menudate     - Set system datetime     - Set system timetimezone - Set system timezoneolddst   - Set system DST for US prior to 2007dlight   - Set system daylight savingsidle     - Set timeout for idle CLI sessionsnotice   - Set login noticebannr    - Set login bannerhprompt  - Enable/disable display hostname (sysName) in CLI promptbootp    - Enable/disable use of BOOTPdhcp     - Enable/disable use of DHCP on Mgmt interfacereminder - Enable/disable Remindersrstctrl  - Enable/disable System reset on paniccur      - Display current system-wide parameters>> System# access
------------------------------------------------------------
[System Access Menu]mgmt     - Management Network Definition Menuuser     - User Access Control Menu (passwords)https    - HTTPS Web Access Menusnmp     - Set SNMP access controltnport   - Set Telnet server port numbertport    - Set the TFTP Port for the systemwport    - Set HTTP (Web) server port numberhttp     - Enable/disable HTTP (Web) accesstnet     - Enable/disable Telnet accesstsbbi    - Enable/disable Telnet/SSH configuration from BBIuserbbi  - Enable/disable user configuration from BBIcur      - Display current system access configuration>> System Access# user
------------------------------------------------------------
[User Access Control Menu]uid      - User ID Menueject    - Eject userusrpw    - Set user password (user)opw      - Set operator password (oper)admpw    - Set administrator password (admin)cur      - Display current user status>> User Access Control# curUsernames:user     - enabled    - offline   oper     - disabled   - offline   admin    - Always Enabled - online     3 sessions.

可见缺省有3个用户,其中user和admin是可用状态。

通过在cfg-sys-access-user层级的usrpw和admpw指令可以分别对user和admin用户指令进行修改。修改以后diff可以显示配置变化,apply可使修改生效,save可以保存修改到永久文件。凡是修改,apply-save是必须要做的。

2、图形界面修改

1、帐户管理的图形界面如下:

 执行修改用户名密码会报错:

 2、需要先在命令行去打开BBI配置功能,操作如下:

------------------------------------------------------------
[Main Menu]Jan  3 17:38:25 10.193.199.4 NOTICE  mgmt: admin(admin) login from host 10.227.17.234info     - Information Menustats    - Statistics Menucfg      - Configuration Menuoper     - Operations Command Menuboot     - Boot Options Menumaint    - Maintenance Menudiff     - Show pending config changes  [global command]apply    - Apply pending config changes [global command]save     - Save updated config to FLASH [global command]revert   - Revert pending or applied changes [global command]exit     - Exit  [global command, always available]>> Main# cfg
------------------------------------------------------------
[Configuration Menu]sys      - System-wide Parameter Menuport     - Port Menuqos      - QOS Menuacl      - Access Control List Menupmirr    - Port Mirroring Menul2       - Layer 2 Menul3       - Layer 3 Menurmon     - RMON Menuufd      - Uplink Failure Detection Menusetup    - Step by step configuration set updump     - Dump current configuration to script fileptcfg    - Backup current configuration to FTP/TFTP servergtcfg    - Restore current configuration from FTP/TFTP servercur      - Display current configuration>> Configuration# 
Jan  3 17:38:53 10.193.199.4 NOTICE  mgmt: admin idle timeout from BBI
sys
------------------------------------------------------------
[System Menu]syslog   - Syslog Menusshd     - SSH Server Menuradius   - RADIUS Authentication Menutacacs+  - TACACS+ Authentication Menuntp      - NTP Server Menussnmp    - System SNMP Menuaccess   - System Access Menudate     - Set system datetime     - Set system timetimezone - Set system timezoneolddst   - Set system DST for US prior to 2007dlight   - Set system daylight savingsidle     - Set timeout for idle CLI sessionsnotice   - Set login noticebannr    - Set login bannerhprompt  - Enable/disable display hostname (sysName) in CLI promptbootp    - Enable/disable use of BOOTPdhcp     - Enable/disable use of DHCP on Mgmt interfacereminder - Enable/disable Remindersrstctrl  - Enable/disable System reset on paniccur      - Display current system-wide parameters>> System# access
------------------------------------------------------------
[System Access Menu]mgmt     - Management Network Definition Menuuser     - User Access Control Menu (passwords)https    - HTTPS Web Access Menusnmp     - Set SNMP access controltnport   - Set Telnet server port numbertport    - Set the TFTP Port for the systemwport    - Set HTTP (Web) server port numberhttp     - Enable/disable HTTP (Web) accesstnet     - Enable/disable Telnet accesstsbbi    - Enable/disable Telnet/SSH configuration from BBIuserbbi  - Enable/disable user configuration from BBIcur      - Display current system access configuration>> System Access# userbbi
Current User config from BBI: disabled
Enter new User config from BBI [d/e]: e>> System Access# diff
=> Pending configuration/c/sys/accessuserbbi ena

apply和save以后,在图形界面重新刷新

即可进行密码修改:

 

这篇关于HP C7000刀片服务器北电GbE2c背板网络交换机更改用户名密码的文章就介绍到这儿,希望我们推荐的文章对编程师们有所帮助!



http://www.chinasem.cn/article/245425

相关文章

Python极速搭建局域网文件共享服务器完整指南

《Python极速搭建局域网文件共享服务器完整指南》在办公室或家庭局域网中快速共享文件时,许多人会选择第三方工具或云存储服务,但这些方案往往存在隐私泄露风险或需要复杂配置,下面我们就来看看如何使用Py... 目录一、android基础版:HTTP文件共享的魔法命令1. 一行代码启动HTTP服务器2. 关键参

SpringBoot改造MCP服务器的详细说明(StreamableHTTP 类型)

《SpringBoot改造MCP服务器的详细说明(StreamableHTTP类型)》本文介绍了SpringBoot如何实现MCPStreamableHTTP服务器,并且使用CherryStudio... 目录SpringBoot改造MCP服务器(StreamableHTTP)1 项目说明2 使用说明2.1

Linux中压缩、网络传输与系统监控工具的使用完整指南

《Linux中压缩、网络传输与系统监控工具的使用完整指南》在Linux系统管理中,压缩与传输工具是数据备份和远程协作的桥梁,而系统监控工具则是保障服务器稳定运行的眼睛,下面小编就来和大家详细介绍一下它... 目录引言一、压缩与解压:数据存储与传输的优化核心1. zip/unzip:通用压缩格式的便捷操作2.

Spring Security中用户名和密码的验证完整流程

《SpringSecurity中用户名和密码的验证完整流程》本文给大家介绍SpringSecurity中用户名和密码的验证完整流程,本文结合实例代码给大家介绍的非常详细,对大家的学习或工作具有一定... 首先创建了一个UsernamePasswordAuthenticationTChina编程oken对象,这是S

mysql中的服务器架构详解

《mysql中的服务器架构详解》:本文主要介绍mysql中的服务器架构,具有很好的参考价值,希望对大家有所帮助,如有错误或未考虑完全的地方,望不吝赐教... 目录1、背景2、mysql服务器架构解释3、总结1、背景简单理解一下mysqphpl的服务器架构。2、mysjsql服务器架构解释mysql的架

Linux如何快速检查服务器的硬件配置和性能指标

《Linux如何快速检查服务器的硬件配置和性能指标》在运维和开发工作中,我们经常需要快速检查Linux服务器的硬件配置和性能指标,本文将以CentOS为例,介绍如何通过命令行快速获取这些关键信息,... 目录引言一、查询CPU核心数编程(几C?)1. 使用 nproc(最简单)2. 使用 lscpu(详细信

PostgreSQL数据库密码被遗忘时的操作步骤

《PostgreSQL数据库密码被遗忘时的操作步骤》密码遗忘是常见的用户问题,因此提供一种安全的遗忘密码找回机制是十分必要的,:本文主要介绍PostgreSQL数据库密码被遗忘时的操作步骤的相关资... 目录前言一、背景知识二、Windows环境下的解决步骤1. 找到PostgreSQL安装目录2. 修改p

MySQL MCP 服务器安装配置最佳实践

《MySQLMCP服务器安装配置最佳实践》本文介绍MySQLMCP服务器的安装配置方法,本文结合实例代码给大家介绍的非常详细,对大家的学习或工作具有一定的参考借鉴价值,需要的朋友参考下... 目录mysql MCP 服务器安装配置指南简介功能特点安装方法数据库配置使用MCP Inspector进行调试开发指

在Windows上使用qemu安装ubuntu24.04服务器的详细指南

《在Windows上使用qemu安装ubuntu24.04服务器的详细指南》本文介绍了在Windows上使用QEMU安装Ubuntu24.04的全流程:安装QEMU、准备ISO镜像、创建虚拟磁盘、配置... 目录1. 安装QEMU环境2. 准备Ubuntu 24.04镜像3. 启动QEMU安装Ubuntu4

Druid连接池实现自定义数据库密码加解密功能

《Druid连接池实现自定义数据库密码加解密功能》在现代应用开发中,数据安全是至关重要的,本文将介绍如何在​​Druid​​连接池中实现自定义的数据库密码加解密功能,有需要的小伙伴可以参考一下... 目录1. 环境准备2. 密码加密算法的选择3. 自定义 ​​DruidDataSource​​ 的密码解密3